1300 789 545

safetylink@heightsafety.com



         WindowLink



WINDOWLINK ROOF ANCHOR

SafetyLink's patented WindowLink is an anchor point used in concrete or steel column structures. The WindowLink can be placed outside or within the building, creating easy access for window maintenance.

• Non obtrusive concrete anchor designed to swivel 360 degrees.
• Built in shock absorber.
• Discreet stainless steel cover.
• Designed to be chemically anchored or bolted to steel.
• Tested to Australian New Zealand Standards.



Components

PRODUCT CODE QUANTITY
WINDW001 1


POSITIONING OF CONCRETE ANCHOR POINT
(refer to appendix diagrams 2 and 3 of the Handbook)

The first ConcreteLink Anchor Point must be in a position easily and safely reached by a secured ladder or a manhole access point.

Testing for Free fall-arrest for one person. 15 kN ultimate strength
1. To comply with Australian Standards each ConcreteLink unit must be tested after installation.
2. Allow sufficient time for curing before testing, see instructions on fastener container.
3. Test consists of ultimate pull out force proof loading to 50% of design purpose of anchorage.
4. Recommended chemical anchor: Hilti RE500 or Hilti HY200 as per Hilti Product Supplement Data Sheets. Read instructions on product carefully. The entire surface of the ConcreteLink unit that is in contact with the concrete must have sufficient adhesive gel, as specified on the product.   


Related Products

ConcreteLink Hydrajaws Tester SwiveLink with nut