An anchor point designed for use on timber structures where there is easy access to the top of the rafter.



Components

PRODUCT CODE QUANTITY
HINGE001.01 1
HINGE001.02 1
HINGE001.03 1


POSITIONING OF HINGELINK ANCHOR POINT
(refer to appendix diagrams 2 and 3 of the Handbook) The first HingeLink anchor point must be in a position easily and safely reached by a secured ladder or a manhole access area. 

INSPECT THE TIMBER FOR STRENGTH
Install anchors only to timber strong enough to support the anchor point. Minimum timber size is 35mm by 90mm (grade F5). Inspect the timber for splits, cracks, knots and white ant damage. Ensure the timber structure is secured in accordance with Australian Building Codes.    